Lp. |
Description |
1 |
Core type: Rigid Polyisocyanurate Foam (PIR) |
2 |
Density [kg/m3]: p = 30 kg/m3 |
3 |
Declared heat transfer coefficient λ:
- λD = 0,027 for 20 ≤ d < 80 mm
- λD = 0,026 for 80 ≤ d ≤ 120 mm
- λD = 0,025 for 120 < d ≤ 250 mm
|
4 |
Cladding type: Double-sided panel cladding made of glass veil (WS). |
5 |
Standard board dimensions [mm]: 600 x 1200 ; 1200 x 2400 |
6 |
Available board dimensions [mm]: 1000 x 1200 ; 1200 x 1200 ; 1800 x 1200 ; 1200 x 3000 |
7 |
Cutters*: FIT - flat cutter, LAP - stepped cutter, TAG - tongue and groove cutter |
8 |
Available panel thicknesses: from 20 - 250 mm |
9 |
Plate thickness [mm]:
- 20
- 30
- 40
- 50
- 60
- 70
- 80
- 90
- 100
- 110
- 120
- 130
|
10 |
Thermal resistance RD:
- 0,70
- 1,10
- 1,45
- 1,85
- 2,20
- 2,25
- 3,05
- 3,45
- 3,80
- 4,20
- 4,80
- 5,20
|
11 |
U-value for the roof:
- 1,14
- 0,80
- 0,62
- 0,50
- 0,42
- 0,37
- 0,31
- 0,28
- 0,25
- 0,23
- 0,20
- 0,19
|
12 |
Heat transfer coefficient U for wall and floor:
- 1,10
- 0,78
- 0,61
- 0,49
- 0,42
- 0,36
- 0,31
- 0,28
- 0,25
- 0,23
- 0,20
- 0,19
|
13 |
Plate thickness [mm]:
- 140
- 150
- 160
- 170
- 180
- 190
- 200
- 210
- 220
- 230
- 240
- 250
|
14 |
Thermal resistance RD:
- 5,60
- 6,00
- 6,40
- 6,80
- 7,20
- 7,60
- 8,00
- 8,40
- 8,80
- 9,20
- 9,60
- 10,0
|
15 |
U-value for the roof:
- 0,17
- 0,16
- 0,15
- 0,14
- 0,14
- 0,13
- 0,12
- 0,12
- 0,11
- 0,11
- 0,10
- 0,10
|
16 |
Heat transfer coefficient U for wall and floor:
- 0,17
- 0,16
- 0,15
- 0,14
- 0,14
- 0,13
- 0,12
- 0,12
- 0,11
- 0,11
- 0,10
- 0,10
|
17 |
Reaction to fire (single panel): 20-49: class F, 50-250: class E |
18 |
Reaction to fire (in the system): B-s2,d0 (trapezoidal sheet) |
19 |
Broof(t1) / NRO: Broof(t1) (glued mechanism) |
20 |
Fire resistance: REI 30/REI 15 (according to Fires/ITB) (from 70 mm - 250 mm) |
Reviews