No. |
Description |
Data |
1 |
Core type |
Hard mineral wool |
2 |
Thermal conductivity coefficient λD [W/m*K]. |
0,044 |
3 |
Thickness [mm] |
100, 120, 160, 200, 250 |
4 |
Weight [kg/1mb] for 0.5/0.6 mm cladding (1000 mm module) |
20,0, 22,1, 26,3, 30,5, 35,8 |
5 |
Weight [kg/1mb] for 0.5/0.6 mm cladding (1140 mm module) |
22,7, 25,1, 29,9, 34,7, 40,7 |
6 |
Ud,S [W/m2K] mineral wool core |
0,43, 0,36, 0,27, 0,22, 0,17 |
7 |
Modular width [mm] |
1000 / 1140 |
8 |
External profiling 1000 |
L - linear, M - microprofiled, F - corrugated, R - grooved |
9 |
External profiling 1140 |
L - linear, M - microprofiled, F - corrugated |
10 |
Profiling of the inner lining |
L - Linear |
11 |
Reaction to fire (for all end uses) |
A2-s1,d0 |
12 |
Fire spread |
NRO |
13 |
Fire resistance classification |
EI 120, EI 180, EI 240 |
14 |
Water vapour permeability |
"Meets requirements" (Impervious) |
15 |
Sound insulation |
31(-2;-3) |
16 |
Standard colours of the external cladding for modular widths of 1000 mm |
RAL 9002, RAL 9006, RAL 9007, RAL 9010 |
17 |
Standard colours of the outer cladding for a modular width of 1140 mm |
RAL 7016, RAL 9002, RAL 9006, RAL 9007, RAL 9010 |
18 |
Standard colours of the interior cladding |
RAL 9002, RAL 9010 |
19 |
Certificates, approvals |
PZH approval, EN 14509:2013 |
* Conversion table of panel weights with other cladding thicknesses available from the Technical Department. |
** Colours available depending on cladding thickness. |
*** Conditions by fire resistance classification. Details of horizontal and vertical fire resistance classification in the DWU. |