Technical data
1 |
Kind of core:
|
Rigid polyisocyanurate foam(PIR)
|
|||||||||||
2 |
Density [kg/m3]:
|
p = 30 kg/m3 | |||||||||||
3 |
Declared heat transfer coefficient for lining λ:
|
λD = 0,027 for 20 ≤ d < 80 mm |
λD = 0,026 for 80 ≤ d ≤ 120 mm |
λD = 0,025 for 120 < d ≤ 250 mm |
|||||||||
4 |
Type of facing:
|
Double-sided gas-permeable lining impregnated with bitumen glass veil (BT).
|
|||||||||||
5 |
Standard board dimensions [mm]:
|
600 x 1200 ; 1200 x 2400 | |||||||||||
6 |
Available boards dimensions [mm]:
|
1000 x 1200 ; 1200 x 1200 ; 1800 x 1200 ; 1200 x 3000
|
|||||||||||
7 |
Joint types*:
|
FIT – flat milling, LAP – stepwise milling, TAG – tongue and groove
|
|||||||||||
8 |
Available boards thicknesses [mm]:
|
from 20 to 250 mm
|
|||||||||||
9 |
Board thickness [mm]:
|
20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | 110 | 120 | 130 |
10 |
Thermal resistance RD:
|
0,70 | 1,10 | 1,45 | 1,85 | 2,20 | 2,65 | 3,05 | 3,45 | 3,80 | 4,20 | 4,80 | 5,20 |
11 |
Heat transfer coefficient U for roof:
|
1,14 | 0,80 | 0,62 | 0,50 | 0,42 | 0,37 | 0,31 | 0,28 | 0,25 | 0,23 | 0,20 | 0,19 |
12 |
Heat transfer coefficient U for wall and floor:
|
1,10 | 0,78 | 0,61 | 0,49 | 0,42 | 0,36 | 0,31 | 0,28 | 0,25 | 0,23 | 0,20 | 0,19 |
13 |
Board thickness [mm]:
|
140 | 150 | 160 | 170 | 180 | 190 | 200 | 210 | 220 | 230 | 240 | 250 |
14 |
Thermal resistance RD:
|
5,60 | 6,00 | 6,40 | 6,80 | 7,20 | 7,60 | 8,00 | 8,40 | 8,80 | 9,20 | 9,60 | 10,00 |
15 |
Heat transfer coefficient U for roof:
|
0,17 | 0,16 | 0,15 | 0,14 | 0,14 | 0,13 | 0,12 | 0,12 | 0,11 | 0,11 | 0,10 | 0,10 |
16 |
Heat transfer coefficient U for wall and floor:
|
0,17 | 0,16 | 0,15 | 0,14 | 0,14 | 0,13 | 0,12 | 0,12 | 0,11 | 0,11 | 0,10 | 0,10 |
17 |
Reaction to fire (single board):
|
F
|
Reviews